IMPROVE Logo Image
IMPROVE Anniversery Logo

The Winter Haze Intensive Tracer Experiment (WHITEX)

whitex

Background

This study was designed to evaluate the feasibility of attributing single point source emissions to visibility impairment in Grand Canyon National Park. WHITEX was conducted during a six week period in January and February 1987. During this time, an artificial tracer, deuterated methane (CD4), was released from the NGS at Page, AZ near the eastern end of the Grand Canyon. Aerosol, optical, tracer, and other properties were measured at Hopi Point (on the south rim of the Grand Canyon) and other locations. Using the tracer, 70% to 80% of the sulfate at Hopi Point under certain meteorological conditions in the winter was attributed to the NGS (Malm et al., 1989b). Some controversy arose from this attribution since the ratio of the CD4 emissions rate to power plant load was not maintained at a stable value (Markowski, 1992). 

In addition, while the measurement of CD4 concentrations is quite precise, the analytical costs are high. As a result, only a fraction of the samples collected were ever analyzed. WHITEX demonstrated the potential of tracer techniques for single source attribution. The study also showed that maintaining a stable tracer/power load emission ratio and using a low cost tracer analytical technique could improve the quality of the source attribution.

Reports

Final Report: Winter Haze Intensive Tracer Experiment

Selected peer reviewed articles from the AWMA/EPA Visibility & Fine Particles Specialty Conference held in Estes Park, Colorado, October 1989: